| Discrete I/O Modules, G2-1 Fieldbus Electronics |
Discrete I/O modules are used to connect additional I/O devices to the valve manifold node. This provides for more efficient use of system resources when configuring a communication system.
Universal input modules feature technology that allows the same module to automatically recognize PNP or NPN type sensors without the need to add external pull-up or pull-down resistors, or manually select sensor type.
Input and output modules have two 12mm (micro) connectors. Each can be used individually (i.e. one I/O point per connector) or can be used for double point (i.e. connector 1 has two points of I/O). This standard feature further simplifies external I/O wiring.
Sub-D output module can be used to drive 16 additional coils on a separate manifold, or 16 discrete output points.
Sub-D I/O module can be used for inputs and or up to a total of 16 I/O points.
Standard Specifications:
- Inputs:
Type: Sourcing (PNP), Sinking (NPN), or contact closure (universal input technology)
LED Indicator: Input Status
- Outputs:
Current: 0.5 amperes per output (4 amps max. per manifold)
LED Indicator: Output Status
- Temperature Range: +32°F to +115°F / 0°C to +46°C
- Humidity: 95% relative humidity, non-condensing
- Moisture: NEMA 4/IP65